Presses 21 to 24. Aug 19 night shift. ERP downtime log.
The presses stopping one by one, then restarting together
What it shows: The ERP shows each press stopping one after another, logged as out of plastic, and when each started again.
Why it proves the point: They ran dry one by one and all restarted at the same minute, so the shared line failed, not any one press.
From the plant's ERPERP downtime log
| Press | Stopped | Restarted | Stopped for |
|---|---|---|---|
| Press 21 | 11:20 pm | 1:15 am | 1 hour 55 minutes |
| Press 22 | 11:30 pm | 1:15 am | 1 hour 45 minutes |
| Press 23 | 11:40 pm | 1:15 am | 1 hour 35 minutes |
| Press 24 | 11:50 pm | 1:15 am | 1 hour 25 minutes |